The JAB D.U.C. is made from DUPLEX 2304 stainless steel giving the unit the strength for high pressure service but light enough for installation.

With a range including slim units and horizontal units it has never been easier to find the perfect location for installation.

 

 

COLD WATER SUPPLY
Telford Stainless unvented cylinders are capable
of delivering up to 55 litres of hot water per
minute given an adequate supply. The minimum
recommended supply is 20 litres per minute at
1.5 bar.
WHAT BOILER SHOULD I USE?
To ensure peak performance and efficiency
the cylinder should ideally be connected to an
oil-fired or gas condensing boiler. The primary
circuit must be pumped and can be open vented
or sealed. Energy requirement (BTU/KWH) will
vary according to cylinder volume.
LOCATION
Our stainless cylinders can be sited virtually
anywhere in the home, but consideration must
be given to service clearances and the weight of
the cylinder when filled.
CONNECTION DIAMETERS
DOMESTIC SIDE
Cold water inlet and hot water
draw-off 3/4” female.
PRIMARY SIDE
Coil flow and return - 3/4” female
SAFETY VALVES
Temperature and pressure relief - Inlet
group 15mm x 15mm pressure
relief - 15mm
TUNDISH
15mm x 22mm compression
SECONDARY RETURN
Standard on cylinders 200L and above

 

COLD WATER SUPPLY

JAB DUC 2 Stainless unvented cylinders are capable

of delivering up to 55 litres of hot water per

minute given an adequate supply. The minimum

recommended supply is 20 litres per minute at

1.5 bar.

 

WHAT BOILER SHOULD I USE?

To ensure peak performance and efficiency

the cylinder should ideally be connected to an

oil-fired or gas condensing boiler. The primary

circuit must be pumped and can be open vented

or sealed. Energy requirement (BTU/KWH) will

vary according to cylinder volume.

 

LOCATION

Our stainless cylinders can be sited virtually

anywhere in the home, but consideration must

be given to service clearances and the weight of

the cylinder when filled.

 

CONNECTION DIAMETERS

 

DOMESTIC SIDE

Cold water inlet and hot water

draw-off 3/4” female.

 

PRIMARY SIDE

Coil flow and return - 3/4” female

 

SAFETY VALVES

Temperature and pressure relief - Inlet

group 15mm x 15mm pressure

relief - 15mm

 

TUNDISH

15mm x 22mm compression

SECONDARY RETURN

 

Standard on cylinders 200L and above

 

DIRECT STANDARD

jaddirectdata.JPG

 

INDIRECT STANDARD

jadindirectdata.JPG

 

DIRECT SLIM

jaddirectslimdata.JPG

 

INDIRECT SLIM

jadindirectslimdata.JPG

 

INDIRECT SOLAR

jadindirectsoldata.JPG

 

HORIZONTAL

jadhordata.JPG